A Low Cost Baby Incubator Design Equipped with Vital Sign Parameters

Baby Incubator, Temperature, Humidity, Oxygen Saturation, Heart rate

Authors

  • Lamidi Lamidi Department of Medical Electronics Engineering Technology of Politeknik Kesehatan Kementerian Kesehatan Surabaya, Indonesia, Indonesia
  • Abd Kholiq Department of Electromedical Engineering Poltekkes Kemenkes, Surabaya, Indonesia, Indonesia
  • Muslim Ali University of Gezira, University City,Wadmedani, Gezira State, Sudan, Sudan
Vol. 3 No. 2 (2021): May
Medical Engineering
August 17, 2025
August 17, 2025

Downloads

The aim of this study was to create a compact system at a low cost in an infant incubator. Apart from stabilizing the temperature, it can also calculate the premature baby's heart rate and oxygen saturation value. The contribution of the system being built can detect the early symptoms of congenital abnormalities so that abnormalities detection becomes more practical. The temperature stability in this system uses a threshold system, where the sensor readings are compared with the set point value. Meanwhile, the SpO2 system uses a finger sensor attached to the baby's finger to detect oxygen saturation and heart rate. The signal from the sensor is processed in a signal conditioning circuit consisting of an astable circuit, filter and amplifier, LPF, and demultiplexer. Based on the results of testing and measurement, the difference produced by this tool is only 0.13 - 0.182 ° C. The biggest error in the system is 0.517%. Measurement of skin temperature was carried out on 10 respondents with an average value of 34.825 ° C. so that the difference generated from this tool is only 0.175 ° C, the difference on the Humidity parameter is 0.21%. The average BPM reading of respondent 1 was 81 beats per minute and the average SpO2 value was 97%. The average BPM reading of respondent 2 was 83 beats per minute and the average SpO2 value was 98%. You can see that the module with the Arduino control system can work automatically and is able to adjust the stability of the baby incubator according to the settings. In addition, the BPM and SpO2 systems are within tolerance so they can be used for patient measurements

How to Cite

Lamidi, L., Kholiq, A., & Ali, M. (2025). A Low Cost Baby Incubator Design Equipped with Vital Sign Parameters . Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics, 3(2), 53-58. https://doi.org/10.35882/ijeeemi.v3i2.203

Most read articles by the same author(s)

Similar Articles

1-10 of 86

You may also start an advanced similarity search for this article.